Calculating Heat Load for a Circuit

August 24, 2022 Application Procedure Use the following formula and method to calculate heat load for one cooling circuit. This will help determine suitability of the Smartflow Mold Temperature Regulator to your process. NOTE: These graphs and information are intended as a general guide for sizing and initial setup of the mold temperature regulator. Due…
-
Mold Clamps, Bolts & Washers

Molding Safety Checklist June 9, 2022 Inspection Inspect the press and surrounding areas including all auxiliary equipment for the following: Holes in Platens Mold Clamps Clamp Installation Closed-Toe Mold Clamps For basic applications use mold clamps that have a slot to accept the bolt. They never fall off the bolt. Open-Toe Mold Clamps Take great…
-
Molecular Sieve Desiccant

June 2, 2022 Why Buy High-Quality Desiccant? Desiccants can get contaminated or ruined by off-gases of certain resins. A general rule is to change the desiccant every 18 months. Molding problems, particularly in humid months, often trace back to poor drying caused by stale desiccant. The fact is this: desiccant goes bad. Desiccant captures moisture…